Error Codes

RSS

Error Code 383

Error Code: DISPENSER CASSETTES LOW (ALL)

Resolution: All cassettes have reached low cash level. Reload cassettes. Clear the terminal error code.

Error Code 4009600

Error Code: 4009600

Result: Reject error due to the abnormal half of check during check dispense operation

Solution:

1. Check a checks status in the reject box

2. Remoce a dust and foreign objects on te CS31Ab or SC41AB sensors

3. Check the CIU Module Print Head

4. Realign check sheets in teh check cassette box

Reset number of check sheets after troubleshooting

Error Code 4009700

Error Code: 4009700

Result: Reject error due to abnormal check separation interval skew during check dispense operation

Solution:

1. Check a checks status in the reject box

2. Remoce a dust and foreign objects on te CS31Ab or SC41AB sensors

3. Check the CIU Module Print Head

4. Realign check sheets in teh check cassette box

Reset number of check sheets affer troubleshooting

Error Code 4009800

Error Code: 4009800

Result: Abnormal CIU detecting sendor during check dispense operation

Soluion:

1. Clean CS31AB and CS41AB, or remove foreign objects

2. Check if the FM Board CN3 and CIU sensor cable are connected