Error Codes

RSS

Error Code 400A300

Error Code: 400A300

Result: If the shutter cam ins not operated while opening or closing the shutter

Solution:

1. Check if the shutter cams involving operation interferes

2. Check the shutter actuator power cable

3. Check if the TS005 sensor cable is disconnected

4. Exchange a sensor after abnormal operating the TS005 sensor

Error Code 400A400

Error Code: 400A400

Result: Failed to move after collection

Error Code 400A600

Error Code: 400A600

Result: Retract box is full or CS56 sensor is a dark detection

Solution:

1. Remove all cash in retract box

2. Check if there is dust or foreign objects around CS56 sensor and remove them

3. Replace the new sensor

Error Code 400A800

Error Code: 400A800

Result: When cam doesn't arrive at delivery position within regulated time