Error Code 4009900

Error Code: 4009900

Result: CIU communications response timeout error during check dispense reserved operation or initializing

Solution:

1. Reinitialize

2. Check if the CIU communications serial cable is connected

3. Check in the CIU power cable is connected

Error Code 4009A00

Error Code: 4009A00

Result: CS31AB-CS13 sensors are detected as dark due to time out during dispense operation of cassette 3

Solution:

1. Remove jammed notes on CDU notes transport path

2. Remove dust in CS31AB-CS13 sensor

3. Install after rearranging notes in cassette

Error Code 400A000

Error Code: 400A000

Result: Detected the TS103 dark during command reserved operation

Solution:

1. Remoce a jammed note between the retract box and the tray

2. Check if the TS103 sensor cable is disconnected

3. Exchange a sensor after abnormal operating TS103 sensor

Error Code 400A200

Error Code: 400A200

Result: When a note doesn't arrive from the tray to the throat entrance

Solution:

1. Remove a jammed note of foreign objects between the throat and the tray

2. Check if the CS10AB and Cs14 sensor cable is disconnected

3. Check the feed motor operation in the throat unit

4. Exchange a sensor after abnormal operating the CS14 sensor