Error Codes

RSS

Error Code 4008A00

Error Code: 4008A00

Result: CS11AB Dark detection on transport path before dispense operation

Solution:

1. Remove the remaining notes and foreign objects at the postion of the CS11AB

2. Check if the CS11AB sensor cable is disconnected

3. Exchange a sensor after abnormal operating the CS11AB sensor

Error Code 4008B00

Error Code: 4008B00

Result: CS11AB Dark detection on transport path before dispense operation

Solution:

1. Remove the remaining notes and foreign objects at the postion of the CS21AB

2. Check if the CS21AB sensor cable is disconnected

3. Exchange a sensor after abnormal operating the CS21AB sensor

Error Code 4008C00

Error Code: 4008C00

Result: CS11AB Dark detection on transport path before dispense operation

Solution:

1. Remove the remaining notes and foreign objects at the postion of the CS31AB

Check if the CS31AB sensor cable is disconnected

3. Exchange a sensor after abnormal operating the CS31AB sensor

Error Code 374

Error Code 374: DISPENSER REJECTED CHEQUE

Resolution: 1. Power down the ATM in the proper sequence. From the Main Menu screen, select System Parameters (5) followed by Shut Down the Terminal (4). When the indication that it is safe to turn off the terminal is displayed on the screen push the Power ON/OFF switch to the OFF position. After about ten seconds, push the Power ON/OFF switch to the ON position to start the terminal.

2. Clear the terminal error code. Replace the dispenser mechanism if the error persists.