Error Codes
Error Code 392
Error Code 392: ERROR IN LAST DISPENSE
Resolution:
1. Power down the ATM in the proper sequence. From the Main Menu screen, select System Parameters (5) followed by Shut Down the Terminal (4). When the indication that it is safe to turn off the terminal is displayed on the screen push the Power ON/OFF switch to the OFF position. After about ten seconds, push the Power ON/OFF switch to the ON position to start the terminal.
2. Reset the error code.
3. Replace the dispenser if the error code persists.
Error Code 391
Error Code 391: DISPENSER SENSOR FAILURE
Resolution:
Access the management function diagnostics menu to verify the operational status of the sensors. Clean the sensors as needed. Replace the dispenser components or dispenser if the error persists.
Error Code 9780097
Error Code: 9780097
Result: Wrong position in stack
Resolution: Reject the check and Insert the check in right position
Error Code 390
Error Code 390: DISPENSER OFFLINE - STORING CONFIGURATION
Resolution:
1. Power down the ATM in the proper sequence. From the Main Menu screen, select System Parameters (5) followed by Shut Down the Terminal (4). When the indication that it is safe to turn off the terminal is displayed on the screen push the Power ON/OFF switch to the OFF position. After about ten seconds, push the Power ON/OFF switch to the ON position to start the terminal.
2. Verify the error code lights on the dispenser are operating in proper sequence.
3. Use the NMD test sofware (available to Triton Certified Service Technicians) and verify the operational error code of the dispenser.