Error Codes
Error Code 109
Error Code 109: TIME-OUT AT EXIT SENSOR
Resolution:
1. Inspect for jammed currency in the feed path and at the Exit sensor. Remove any jammed currency.
2. Purge the dispenser using the PURGE command. Test the dispensing mechanism by completing several Test Dispenses.
3. If the error clears, put the ATM into service. Otherwise, replace the dispensing mechanism.
Error Code 108
Error Code 108: UNEXPECTED NOTE AT DOUBLE DETECT
Resolution:
1. Inspect the dispensing mechanism for damaged components or broken wires.
2. Remove the cassette and visually inspect for loose or disconnected connectors on both the upper and lower width sensor printed circuit boards.
3. If there is no visible damage and the connectors are attached to the sensor boards, the best course of action is to replace the dispensing mechanism.
Need a new dispenser? Check out these ATM dispensers for sale
Error Code 106
Error Code 106: FIFO ERROR
Resolution:
1. The dispensing mechanism may have corrupt software. Power down the ATM in the proper sequence. From the Main Menu screen, select System Parameters (5) followed by Shut Down the Terminal (4). When the indication that it is safe to turn off the terminal is displayed on the screen, push the Power ON/OFF switch to the OFF position. After about ten seconds, push the Power ON/OFF switch to the ON position to start the terminal.
2. Purge the dispenser using the PURGE command. Test the dispensing mechanism by completing several test dispenses.
3. If the error clears, put the ATM into service. If the error persists, replace the dispensing mechanism.
Error Code 105
Error Code 105: INSUFFICIENT NOTES TO LEARN FROM
Resolution:
There may be an insufficient number of notes in the cassette to complete the requested amount (minimum number of 15 notes). Press the "learn note thickness" command. Put more currency in the cassette and repeat the "learn note thickness" command.