Error Codes

RSS

Error Code 4003B00

Error Code 4003B00

Result: When CS15A or CS 15B sensor is detected as dark after initial recovery.

Solution:

1. Remove notes or dust on CS15A Sensor.

2. Check CS15A Sensor Cable.

3. Exchange Sensor after abnormal operating CS15A Sensor.

Error Code 4004000

Error Code 4004000

Result: CASSETTE IS REMOVED DURING DISPENSING 

Solution:

1. Check the cassette catcher.

2. Set the cassette properly.

Error Code 4004100

Error Code 4004100

Result: ERROR IF RE-DRIVING IS OVER 5 TIMES DURING SEPARATED REJECTION 

Solution:

1. Check notes in Reject Box.

2. Rearrange notes in Cassette.

3. Remove dust in CS15AB, CS31AB, CS41AB, CS1AB Sensor.

4. Check dust existing in CS5 Sensor Guide.

5. Check dust existing in Main Motor Encoder Slit.

6. Check index value of notes each cassette.

Error Code 4004200

Error Code 4004200

Result: In case the number of notes detected by outlet sensor(CS13) is less than the number of required notes.

Solution:

1. Check notes dispensed and rejected.

2. Remove notes jammed in CDU.

3. Remove dust in CS13 Sensor.

4. Exchange sensor after abnormal operating CS13 Sensor.