Error Codes
Error Code 4003700
Error Code 4003700
Result: Error of 2 sheets detecting sensor (CS5_1 /CS5_2) for dispensing.
Solution:
1. Check Cash Dispenser Board Segment.
2. Initialize.
3. Read data of ‘Read Double Sensor’ Command.
Error Code 4003900
Error Code 4003900
Result: Gate operation sensor (CS3) error before initial recovery.
Solution:
1. Initialize after removing notes or dust over Gate.
2. Check CS3 Sensor BKRT.
3. Check CS3 Sensor Cable.
4. Exchange Sensor after abnormal operating CS3 Gate detecting Sensor.
5. Replace Reject Solenoid 1.
Error Code 4003A00
Error Code 4003A00
Result: When more than 5 sheets of cash dispensing is required during a test.
Solution:
1. Check command that Cash Dispenser is received.
2. Check Cash Dispenser EP ROM Version or specification.