Error Code 400E300
Error Code: 400E300
Result: Dark light sensor test error during initializing
Solution:
1. Check if each sensor is mounted
2. If error occurs when checking the CS31A of CS31B disconnection operation, replace a sensor
Error Code 400E700
Error Code: 400E700
Result: Dark light sensor test error during initializing
Solution:
1. Check if each sensor is mounted
2. If error occurs when checking CS10 disconnection operation, replace a sensor
3. IF error occurs when checking CS9 disconnection operation, erplace a sensor
Error Code 400E600
Error Code: 400E600
Result: Dark light sensor test error during initializing
Solution:
1. Check the CDU information setting
2. Check if each sensor is mounted
3. If error occurs when checing the CS41B disconnection operation, replace a sensor
4. If error occurs when checking the CS41A disconnection operation, replace a sensor
Error Code 400EA00
Error Code: 400EA00
Result: Dark light test error of bill empty sensor on initializing
Solution:
1. Check if each sensor is mounter
2. If error occurs when checking CS18 cable operation, replace a sensor
3. IF error occurs when checking Cs28 cable operation, replace a sensor
4. If error occurs when checking CS38 cable operation, replace a sensor
5. If error occurs when cehcking CS48 cable operation, replace a sensor