Error Codes
Error Code 400E100
Error Code: 400E100
Result: Dark light sensor test error during initializing
Solution:
1. Check if a sensor is mounted
2. If error occurs when checking CS13 cable operation, replace a sensor
Error Code 400DE00
Error Code: 400DE00
Result: Mounting/demounting 4th cassette during dispense operation
Solution:
1. Check notes status in 4th cassette
2. Check 4th cassette specifications
3. If error occurs when checking the CS47s disconnection and operation, replace a sensor
Error Code 400DF00
Error Code: 400DF00
Result: 4th cassette miss feed during dispense
Solution:
1. Check the remaining notes in the 4th cassette
2. Check if the 4 cassette remaining note sensor is normal
3. Check a jammed note in 4th cassette or remount it
4. Remvoe the dust on the CS41A and CS41B sensors
5. Replace 4 cassette box when multiple error occurred
Error Code 400E00
Error Code: 400E00
Result: Dark light sensor test error during initializing
Solution:
1. Check if each sensor is mounted
2. If error occurs when checking CS1A cable operation, replace sensor
3. If error occurs when checking CS1B cable operation, replace sensor
4. If error occurs when checking CS4A cable operation, replace sensor
5. If error occurs when checking CS4B cable opertaion, replace sensor