Error Codes

RSS

Error Code 400E100

Error Code: 400E100

Result: Dark light sensor test error during initializing

Solution:

1. Check if a sensor is mounted

2. If error occurs when checking CS13 cable operation, replace a sensor

Error Code 400DE00

Error Code: 400DE00

Result: Mounting/demounting 4th cassette during dispense operation

Solution:

1. Check notes status in 4th cassette

2. Check 4th cassette specifications

3. If error occurs when checking the CS47s disconnection and operation, replace a sensor

Error Code 400DF00

Error Code: 400DF00

Result: 4th cassette miss feed during dispense

Solution:

1. Check the remaining notes in the 4th cassette

2. Check if the 4 cassette remaining note sensor is normal

3. Check a jammed note in 4th cassette or remount it

4. Remvoe the dust on the CS41A and CS41B sensors

5. Replace 4 cassette box when multiple error occurred

Error Code 400E00

Error Code: 400E00

Result: Dark light sensor test error during initializing

Solution:

1. Check if each sensor is mounted

2. If error occurs when checking CS1A cable operation, replace sensor

3. If error occurs when checking CS1B cable operation, replace sensor

4. If error occurs when checking CS4A cable operation, replace sensor

5. If error occurs when checking CS4B cable opertaion, replace sensor