Error Codes

RSS

Error Code 2YY15

Error Code 2YY15

Result: A note has been detected on the return path before the Cash Dispenser Unit starts to operate

Solution:

1. Remove the jammed note on the return path.

2. Check if the sensor is polluted.

3. Check if cable is cut or the connector is wrongly inserted.

4. Check logic related to the sensor in the Cash Dispenser Unit board.

Error Code 90001

Error Code 90001

Result: CARD READ ERROR

Solution:

1. Check Magnetic Card.

2. Check Card Read module and cable connection.

Error Code 90002

Error Code 90002

Result: INVALID IC CARD COMMUNICATION

Solution:

1. Power Off/On.

2. Check DIP MCR.

3. Check cable connection.

Error Code 90003

Error Code 90003

Result: DIP MCR LATCH FAILURE

Solution:

1. Power Off/On.

2. Check DIP MCR (Clamp Lever).

3. Check cable connection.