Error Code C0084

Error Code C0084

Result: 

Shutter close error (CS11). Occurs while the shutter is being closed.

Solution:

1. Check if the shutter normally operates and status of CS22 when the shutter is closed.

2. Check CS22.

3. Check logic related to CS11 of the Cash Dispenser Unit board.

Error Code C00AB

Error Code C00AB

Result: 

A note has been detected on the path before the Cash Dispenser Unit initializing

Solution:

1. Remove the jammed note on the path.

2. Check if the sensor is polluted.

3. Check if cable is cut or the connector is wrongly inserted.

4. Check logic related to the sensor in the Cash Dispenser Unit board.

Error Code C00C7

Error Code C00C7

Result: CS12 is Dark while initializing or dispensing (NH2100T).

Solution: 1. Check the sensor.

Error Code C00C8

Error Code C00C8

Result: CS14 is Dark while initializing or dispensing (NH2100T)