Error Codes

RSS

Error Code 4001800

Error Code 4001800

Result: 

CS4B SENSOR DETECTS NOTE IN DELIVERY PATH BEFORE/AFTER CDU DISPENSES 

Solution:

1. Remove note from the CDU delivery path.

2. Clean CS4B.

Error Code 4003300

Error Code 4003300

Result: CHECK SUM ERROR (No information is set.)

Solution:

1. Check Cash Dispenser Information after reading Cash Dispenser version.

2. Initialize.

3. Initialize after executing Cash Dispenser Information Set(‘P’) Command.

4. Change Cash Dispenser B/D

Error Code IDN0X

Error Code IDN0X

Result: DIP MCR CONNECTION FAILURE 

Solution:

1. Power Off/On.

2. Check DIP MCR.

3. Check cable connection.

Error Code 2010900

Error Code 2010900

Result: NO SENSING BLACK MARK (DARK SENSOR) 

Solution: 

1. Check the status of Black mark sensor.

2. Check if Dip switch # 6 is correctly set (Dip switch # 6 is set by On in case of not using Black mark).