Error Codes
Error Code 4001800
Error Code 4001800
Result:
CS4B SENSOR DETECTS NOTE IN DELIVERY PATH BEFORE/AFTER CDU DISPENSES
Solution:
1. Remove note from the CDU delivery path.
2. Clean CS4B.
Error Code 4003300
Error Code 4003300
Result: CHECK SUM ERROR (No information is set.)
Solution:
1. Check Cash Dispenser Information after reading Cash Dispenser version.
2. Initialize.
3. Initialize after executing Cash Dispenser Information Set(‘P’) Command.
4. Change Cash Dispenser B/D
Error Code IDN0X
Error Code IDN0X
Result: DIP MCR CONNECTION FAILURE
Solution:
1. Power Off/On.
2. Check DIP MCR.
3. Check cable connection.
Error Code 2010900
Error Code 2010900
Result: NO SENSING BLACK MARK (DARK SENSOR)
Solution:
1. Check the status of Black mark sensor.
2. Check if Dip switch # 6 is correctly set (Dip switch # 6 is set by On in case of not using Black mark).