Error Codes
Error Code 4005500
Error Code 4005500
Result: Time-out due to note’s length error passed through the CS13 during dispense operation.
Solution:
1. Remove a jammed note between the tray and Cash Dispenser.
2. Remove a jammed note at the position of the CS13 sensor.
3. Remove a dust on the CS13 sensor.
Error Code 4005700
Error Code 4005700
Result: CASH DISPENSER CONFIGURATION ERROR
Solution:
1. Replace cash dispenser PCB.
2. Reconfigure cash dispenser setup data.
Error Code 4005800
Error Code 4005800
Result: Retract box position error during command reserved operation.
Solution:
1. Mount the retract box or open the box cover.
2. Check if CS62 sensor poll is abnormal.
3. Check if the CS62 sensor cable is disconnected (Cash Dispenser Board CN10 #5~2).
Error Code 4005900
Error Code 4005900
Result: INITIAL JAM TIME ERROR
Solution:
1. Remove jammed notes.
2. Clean the sensors (CS1~CS15) in cash dispenser.