Error Codes
Error Code 971D300
Error Code 971D300
Result: PARTIAL DISPENSE FROM CASSETTE #3
Solution:
1. Check the replenished amount and replenish.
2. Check the notes in cassette #3.
Error Code 4003400
Error Code 4003400
Result: Error of two sheets detecting sensor(CS5_1) for initializing.
Solution:
1. Check CS5_1 Sensor Cable.
2. Check second Dip Switch in Cash Dispenser B/D.
3. Change CS5_1 Sensor.
Error Code 4004700
Error Code 4004700
Result: 1 CASSETTE MIS-FEED ERROR (SEPARATED REJECTION)
Solution:
1. Check notes in 1 Cassette.
2. Check Sensor(CS6) Poll.
3. Check jam in 1 cassette and reload.
4. Remove dust in CS1A, CS1B Sensor.
5. Exchange 1 cassette box when there are many errors.
Need a new cassette? Check out these ATM cassettes for sale
Error Code 4004800
Error Code 4004800
Result: ERROR IF THE NUMBER OF DISPENSED NOTES IS NOT MATCHED TO THE REQUESTED
Solution:
1. Check CS13 sensor (note jam and dust).
2. Replace CS13 sensor.